{"title":"Smucker LandMark Poly Tank Foam Marker Parts Breakdown, 2021 to Present","description":"\u003cp\u003eEvery replacement part that fits the LandMark poly tank foam marker built from 2021 forward, in one list. This is the unit with the white plastic enclosure holding the air compressor, the liquid pump and the two solenoid valves.\u003c\/p\u003e\u003cp\u003eMatch the part number on your own machine before you order, since Smucker changed the plumbing on this model more than once. If you cannot read a number off the part, send us a photo through our \u003ca href=\"\/pages\/contact\"\u003econtact form\u003c\/a\u003e and we will identify it.\u003c\/p\u003e","products":[{"product_id":"check-valve-1-4hb-x-1-8mpt-air-in-landmarks-soap-in-injection-lm1825","title":"Check Valve 1\/4\"HB X 1\/8\"MPT Air in Landmarks \u0026 Soap in Injection LM1825","description":"\u003cp\u003eThe two pound check valve used in LandMark foam markers, with a 1\/4 inch hose barb on one end and a 1\/8 inch male pipe thread on the other. Smucker uses it for air on the LandMark markers and for soap on the injection markers, so the same part covers both jobs.\u003c\/p\u003e\u003ch3\u003eDetails\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSmucker part number LM1825\u003c\/li\u003e\n\u003cli\u003eTwo pound check valve\u003c\/li\u003e\n\u003cli\u003e1\/4 inch hose barb by 1\/8 inch MPT\u003c\/li\u003e\n\u003cli\u003eAir on LandMark markers, soap on injection markers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267703206083,"sku":"LM1825","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/lm1825_1af8f8af-8051-4e04-b35c-5d750c1d5d21.png?v=1790475605"},{"product_id":"landmark-3-8-in-mpt-x-1-4-in-hb-elbow-he3814","title":"LandMark 3\/8 in MPT x 1\/4 in HB Elbow HE3814","description":"\u003cp\u003eThe 3\/8 inch male pipe thread by 1\/4 inch hose barb elbow, number 72 on the Smucker parts breakdown. It is found in the foam marker solenoids built before 2013, so check which solenoid you have before ordering.\u003c\/p\u003e\u003ch3\u003eDetails\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSmucker part number HE3814\u003c\/li\u003e\n\u003cli\u003e3\/8 inch MPT by 1\/4 inch hose barb elbow\u003c\/li\u003e\n\u003cli\u003eUsed in pre 2013 foam marker solenoids\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267719852227,"sku":"HE3814","price":1.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/he3814_b911bde0-9c6d-4e3f-86ed-f4e88f57a2eb.png?v=1790477956"},{"product_id":"landmark-air-intake-filter-assembly-th1066","title":"LandMark Air intake Filter Assembly TH1066","description":"\u003cp\u003eThe complete air intake filter assembly for a LandMark foam marker compressor, number 39 on the Smucker parts breakdown. It is the housing and the element together, and it is what keeps field dust out of the compressor.\u003c\/p\u003e\u003cp\u003eDust is the usual cause of a compressor giving out early, so this is worth keeping clean and replacing when the housing cracks. The white felt element on its own is part TH1007.\u003c\/p\u003e\u003ch3\u003eDetails\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSmucker part number TH1066\u003c\/li\u003e\n\u003cli\u003eComplete air intake filter assembly\u003c\/li\u003e\n\u003cli\u003eNumber 39 on the foam marker parts breakdown\u003c\/li\u003e\n\u003cli\u003eFelt element alone is TH1007\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267719884995,"sku":"TH1066","price":13.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/th1066_364cd882-3a40-4ebf-97e7-659e376f77c5.png?v=1790478824"},{"product_id":"landmark-foam-parts-thomas-air-compressor-fm1010","title":"LandMark Foam Parts Thomas Air compressor FM1010","description":"\u003cp\u003eThis Landmark Thomas Air Compressor is used on all of our Landmark Foam Markers both pre-2013 and Post-2013.  The compressor comes with the standard filter used on Landmark products. \u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267719917763,"sku":"fm1010","price":398.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/fm1010_9d601f71-619d-4c5e-9adf-73803188d6eb.png?v=1790477060"},{"product_id":"landmark-foam-marker-brass-needle-valve-lm1818","title":"LandMark Foam marker Brass Needle Valve LM1818","description":"\u003cp\u003eThe brass needle valve that controls flow on a LandMark foam marker. It is used on all LandMark models and threads 1\/8 inch by 1\/8 inch female.\u003c\/p\u003e\u003cp\u003eThis is the valve you turn when the foam is coming out too wet or too dry. If it will no longer hold a setting, or it has seized from sitting through a winter with concentrate in it, replace it rather than forcing it.\u003c\/p\u003e\u003ch3\u003eDetails\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSmucker part number LM1818\u003c\/li\u003e\n\u003cli\u003eBrass needle valve, number 12 on the parts breakdown\u003c\/li\u003e\n\u003cli\u003e1\/8 inch by 1\/8 inch female thread\u003c\/li\u003e\n\u003cli\u003eUsed on all LandMark models\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267719983299,"sku":"LM1818","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/lm1818_9cf756c4-eaa1-4376-b7f2-a3ae6162061f.png?v=1790475605"},{"product_id":"shurflo-pump-w-bypass-1-8-gpm-lm1011","title":"Shurflo Pump w\/ Bypass 1.8 gpm. LM1011","description":"\u003cp\u003eThe pump that moves foam concentrate from the tank to the foam chamber on a LandMark marker. It carries its own bypass, so it can run against a closed line without damaging itself, and the pressure switch is preset at 60 PSI.\u003c\/p\u003e\u003cp\u003eA marker that makes thin foam, or none at all, with the compressor clearly running is usually a pump that has lost its prime or worn out. Check the liquid filter first, then the pump.\u003c\/p\u003e\u003ch3\u003eDetails\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSmucker part number LM1011\u003c\/li\u003e\n\u003cli\u003ePump with built in bypass\u003c\/li\u003e\n\u003cli\u003ePressure switch preset at 60 PSI\u003c\/li\u003e\n\u003cli\u003eFeeds the foam chamber from the concentrate tank\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Smucker Manufacturing","offers":[{"title":"Default Title","offer_id":44267756716227,"sku":"LM1011","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/files\/LM1011_6f92c35d-9291-42fe-92d9-ed28f45d317c.png?v=1790475604"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/1894\/5731\/collections\/Landmark_poly_tank_foam_marker_parts_list.png?v=1791559340","url":"https:\/\/www.petecosupply.com\/collections\/landmark-poly-tank-foam-marker-parts-breakdown.oembed","provider":"PeteCo Supply, LLC. ","version":"1.0","type":"link"}